PVC Insulated Unarmoured Power Cable
PVC Insulated Unarmoured Power Cable
LV PVC Insulated Unarmoured Power Cables Single core(unarmoured)
LV PVC Insulated Unarmoured Power Cables Two cores(unarmoured)
LV PVC Insulated Unarmoured Power Cables Three cores(unarmoured)
LV PVC Insulated Unarmoured Power Cables Three cores+1(unarmoured)
LV PVC Insulated Unarmoured Power Cables Four cores(unarmoured)
LV PVC Insulated Unarmoured Power Cables Multi-cores(unarmoured)
Application
PVC insulated Unarmoured power cables are used for power supply in low voltage installation systems, they are suitable for installation indoors and outdoors, in cable ducts, underground, in power stations and switchyards, local energy distribution, industrial plants, without risk of mechanical damage.
Specifications
Outer sheath
The outer sheath shall be extruded PVC type ST1/ST2, polyethylene type ST3/ST7, halogen-free compound ST8, polychloroprene, chlorosulfonated polyethylene or similar polymers conforming to IEC 60502-1, type SE1 is also available on request.
Fire performance of cable sheath
The cable can be provided with a special flame retardant PVC outer sheath to comply with the flame retardant test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, and halogen-free materials complying with IEC60754-1/2 and IEC 60684-2.
Parameter
Single core(unarmoured) | |||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHT OF CABLE (APPROX.) |
MM2 | MM | MM | MM | MM | KG/KM |
1×4 | 2.6 | 1 | 1.4 | 7.5 | 95 |
1×6 | 3.1 | 1 | 1.4 | 8 | 120 |
1×10 | 4 | 1 | 1.4 | 9 | 165 |
1×16 | 5 | 1 | 1.4 | 10 | 230 |
1×25 | 6.3 | 1.2 | 1.4 | 12 | 340 |
1×35 | 7.4 | 1.2 | 1.4 | 13 | 450 |
1×50 | 8.8 | 1.4 | 1.4 | 14.5 | 570 |
1×70 | 10.6 | 1.4 | 1.4 | 16 | 800 |
1×95 | 12.4 | 1.6 | 1.5 | 18.5 | 1070 |
1×120 | 14 | 1.6 | 1.5 | 20 | 1300 |
1×150 | 15.5 | 1.8 | 1.6 | 22 | 1600 |
1×185 | 17.4 | 2 | 1.7 | 24 | 1980 |
1×240 | 20.3 | 2.2 | 1.7 | 27 | 2560 |
1×300 | 22.7 | 2.4 | 1.8 | 30 | 3180 |
1×400 | 25.4 | 2.6 | 1.9 | 33 | 4060 |
1×500 | 28.8 | 2.8 | 2 | 37 | 5140 |
1×630 | 30.4 | 2.8 | 2.2 | 42 | 6600 |
Two cores(unarmoured) | |||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHTOF CABLE (APPROX.) |
MM2 | MM | MM | MM | MM | KG/KM |
2×1.5 | 1.6 | 0.8 | 1.8 | 12 | 205 |
2×2.5 | 2 | 0.8 | 1.8 | 13 | 250 |
2×4 | 2.6 | 1 | 1.8 | 15 | 330 |
2×6 | 3.1 | 1 | 1.8 | 16 | 400 |
2×10 | 4 | 1 | 1.8 | 17.5 | 525 |
2×16 | 5 | 1 | 1.8 | 20 | 720 |
2×25 | 6.3 | 1.2 | 1.8 | 23.5 | 1030 |
2×35 | 7.4 | 1.2 | 1.8 | 25.5 | 1320 |
2×50 | 8.8 | 1.4 | 1.8 | 28.5 | 1670 |
2×70 | 10.6 | 1.4 | 1.8 | 32 | 2290 |
2×95 | 12.4 | 1.6 | 1.9 | 37 | 3060 |
2×120 | 14 | 1.6 | 2 | 40 | 3700 |
2×150 | 15.5 | 1.8 | 2.2 | 44 | 4500 |
2×185 | 17.4 | 2 | 2.3 | 48 | 5570 |
2×240 | 20.3 | 2.2 | 2.5 | 55 | 7180 |
Three cores(unarmoured) | |||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHT OF CABLE (APPROX.) |
MM2 | MM | MM | MM | MM | KG/KM |
3×1.5 | 1.6 | 0.8 | 1.8 | 13 | 230 |
3×2.5 | 2 | 0.8 | 1.8 | 13.5 | 280 |
3×4 | 2.6 | 1 | 1.8 | 15.5 | 380 |
3×6 | 3.1 | 1 | 1.8 | 17 | 470 |
3×10 | 4 | 1 | 1.8 | 18.5 | 630 |
3×16 | 5 | 1 | 1.8 | 21 | 880 |
3×25 | 6.3 | 1.2 | 1.8 | 24.5 | 1280 |
3×35 | 7.4 | 1.2 | 1.8 | 27 | 1660 |
3×50 | 8.8 | 1.4 | 1.8 | 30 | 2110 |
3×70 | 10.6 | 1.4 | 1.9 | 35 | 2980 |
3×95 | 12.4 | 1.6 | 2 | 40 | 3930 |
3×120 | 14 | 1.6 | 2.1 | 43 | 4780 |
3×150 | 15.5 | 1.8 | 2.3 | 48 | 5880 |
3×185 | 17.4 | 2 | 2.4 | 52 | 7230 |
3×240 | 20.3 | 2.2 | 2.6 | 59 | 9390 |
3×300 | 22.7 | 2.4 | 2.7 | 65 | 11620 |
3×400 | 25.4 | 2.6 | 3 | 72 | 14730 |
Three cores+1(unarmoured) | |||||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHTOF CABLE (APPROX.) | ||
MM2 | (3)MM | (1)MM | (3)MM | (1)MM | MM | MM | KG/KM |
3x 16/10 | 5 | 4 | 1 | 1 | 1.8 | 22 | 1000 |
3x 25/16 | 6.3 | 5 | 1.2 | 1 | 1.8 | 26 | 1460 |
3x 35/16 | 7.4 | 5 | 1.2 | 1 | 1.8 | 28 | 1830 |
3x 50/25 | 8.8 | 6.3 | 1.4 | 1.2 | 1.8 | 32 | 2410 |
3x 70/35 | 10.6 | 7.4 | 1.4 | 1.2 | 1.9 | 36 | 3360 |
3x 95/50 | 12.4 | 8.8 | 1.6 | 1.4 | 2.1 | 41 | 4440 |
3×120/70 | 14 | 10.6 | 1.6 | 1.4 | 2.2 | 46 | 5580 |
3×150/70 | 15.5 | 10.6 | 1.4 | 1.2 | 2.3 | 49 | 6580 |
3×185/95 | 17.4 | 12.4 | 1.6 | 1.4 | 2.5 | 54 | 8200 |
3×240/120 | 20.3 | 14 | 1.6 | 1.4 | 2.6 | 61 | 10570 |
3×300/150 | 22.7 | 15.5 | 1.8 | 1.6 | 2.8 | 67 | 13020 |
3×400/185 | 25.4 | 17.4 | 2 | 1.6 | 3.1 | 75 | 16560 |
Four cores(unarmoured) | |||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHT OF CABLE (APPROX.) |
MM | MM | MM | MM | MM | KG/KM |
4×70 | 10.6 | 1.4 | 2 | 38 | 3760 |
4×95 | 12.4 | 1.6 | 2.1 | 44 | 4960 |
4×120 | 14 | 1.6 | 2.3 | 48 | 6110 |
4×150 | 15.5 | 1.8 | 2.4 | 53 | 7450 |
4×185 | 17.4 | 2 | 2.6 | 58 | 9220 |
4×240 | 20.3 | 2.2 | 2.8 | 65 | 11900 |
4×300 | 22.7 | 2.4 | 3 | 72 | 14730 |
4×400 | 25.4 | 2.6 | 3.3 | 81 | 18830 |
Multi-cores(unarmoured) | |||||
NOMINAL CROSS SECTION | DIAMETER OF CONDUCTOR (APPROX.) | NOMINAL INSULATION THICKNESS | NOMINAL PVC SHEATH THICKNESS | OVERALL DIAMETER (APPROX.) | WEIGHT OF CABLE (APPROX.) |
MM2 | MM | MM | MM | MM | KG/KM |
5×1.5 | 1.6 | 0.8 | 1.8 | 14.5 | 300 |
7×1.5 | 1.6 | 0.8 | 1.8 | 15.5 | 360 |
10×1.5 | 1.6 | 0.8 | 1.8 | 19 | 460 |
12×1.5 | 1.6 | 0.8 | 1.8 | 19.5 | 510 |
14×1.5 | 1.6 | 0.8 | 1.8 | 20 | 570 |
19×1.5 | 1.6 | 0.8 | 1.8 | 22 | 710 |
21×1.5 | 1.6 | 0.8 | 1.8 | 23 | 770 |
24×1.5 | 1.6 | 0.8 | 1.8 | 25 | 870 |
30×1.5 | 1.6 | 0.8 | 1.8 | 26 | 1020 |
40×1.5 | 1.6 | 0.8 | 1.8 | 29 | 1290 |
48×1.5 | 1.6 | 0.8 | 1.8 | 32 | 1520 |
61×1.5 | 1.6 | 0.8 | 1.8 | 35 | 1900 |
5×2.5 | 2 | 0.8 | 1.8 | 16 | 375 |
7×2.5 | 2 | 0.8 | 1.8 | 17 | 460 |
10×2.5 | 2 | 0.8 | 1.8 | 20 | 590 |
12×2.5 | 2 | 0.8 | 1.8 | 21 | 660 |
14×2.5 | 2 | 0.8 | 1.8 | 22 | 740 |
19×2.5 | 2 | 0.8 | 1.8 | 24 | 940 |
21×2.5 | 2 | 0.8 | 1.8 | 25 | 1030 |
24×2.5 | 2 | 0.8 | 1.8 | 27 | 1150 |
30×2.5 | 2 | 0.8 | 1.8 | 29 | 1370 |
40×2.5 | 2 | 0.8 | 1.8 | 32 | 1810 |
48×2.5 | 2 | 0.8 | 1.8 | 36 | 2130 |
61×2.5 | 2 | 0.8 | 1.8 | 39 | 2630 |
PDF Download
PDF Download
Why Choose Us

Contact Us Immediately
Contact Us
- 24-hour online service
- Own factory processing
Product Category
hot-sale product
PVC Insulated Armored LV Power Cable Single core( aluminum wire armoured)
PVC Insulated Armored LV Power Cable Two cores(Galvanized steel wire armoured)
PVC Insulated Armored LV Power Cable Three cores(Galvanized steel wire armoured)
PVC Insulated Armored LV Power Cable Three cores+1(Galvanized steel wire armoured)
PVC Insulated Armored LV Power Cable Four cores(Galvanized steel wire armoured)
NYY-J NYY-O Cable 0.6/1 kV Power and control cables for fixed installation.
Can be used indoors, outdoors, underground, in concrete and in water
PVC insulated Unarmoured power cable
PVC insulated armored power cable
CU/PVC/PVC/SWA/PVC
CU/PVC/SWA/PVC