Aerial Insulated Cable (IEC 60502-1)

Aerial Insulated Cable (IEC 60502-1)

CU/PVC, AAC/PVC, AAAC/PVC, CU/PE, AAC/PE, AAAC/PE
CU/XLPE, AAC/XLPE, AAAC/XLPE
AAC/PVC, AAC/PE, AAC/XLPE

Application

The IEC 60502-1 standard Aerial Insulated Cable LV ABC Cable Aerial Bundle Conductor is overhead power lines and room entrance wires with a rated AC pressure of 1kv and below. ABC Cable has less installation, maintenance, and operating costs, which can achieve greater economic loss and provide higher security and reliability.
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.
LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

Construction
Conductor: Conductors are stranded,circular compacted or uncompacted aluminum, copper , aluminum-alloy, ACSR etc.
Insulation: Thermoplastic polyethylene(PE),polyvinyl chloride (PVC) ,cross-linked polyethylene (XLPE),black color,weather and UV resistant.

Specifications

● GB/T 12527(Equivalent to IEC 60502-1)Aerial Insulated Cables for Rated Voltages up to and Including 1kV
● IEC 60228 Conductors of insulated cables

Parameter

Aerial Insulated Cable IEC 60502-1

Section Area Phase Core Neutral Core Complete Cable
Section Area No. of Wires Conductor Diameter Insulation Thickness Section Area No. of Wire Conductor Diameter Insulation Thickness Approx.
Diameter
Approx.
Weight
mm2 mm2 No. mm mm mm2 No. mm mm mm kg/km
1×10 1×10 7 4.05 1.0 6.1 43
1×16 1×16 7 4.8 1.2 7.2 64
1×25 1×25 7 6 1.2 8.4 92
1×35 1×35 7 7 1.4 9.8 127
1×50 1×50 7 8.1 1.4 11.1 165
1×70 1×70 19 10 1.4 12.8 230
1×95 1×95 19 11.6 1.6 14.8 315
1×120 1×120 19 13 1.6 16.2 390
1×150 1×150 19 14.6 1.8 18.2 476
1×185 1×185 37 16.2 2 20.2 609
2×10 2×10 7 4 1 12.2 85
2×16 2×16 7 4.8 1.2 14.4 128
2×25 2×25 7 6 1.2 16.8 184
2×35 2×35 7 7 1.4 19.6 255
2×50 2×50 7 8.1 1.4 22.2 329
2×70 2×70 19 10 1.4 25.6 459
3×10 3×10 7 4 1 13.1 128
3×16 3×16 7 4.8 1.2 17.4 192
3×25 3×25 7 6 1.2 20.3 276
3×35 3×35 7 7 1.4 21.1 382
3×50 3×50 7 8.1 1.4 23.9 494
3×70 3×70 19 10 1.4 27.6 688
3×95 3×95 19 11.6 1.6 31.9 943
3×120 3×120 19 13 1.6 34.9 1170
4×10 4×10 7 4 1 14.6 171
4×16 4×16 7 4.8 1.2 17.4 256
4×25 4×25 7 6 1.2 20.3 368
4×35 4×35 7 7 1.4 23.7 509
4×50 4×50 7 8.1 1.4 26.8 659
4×70 4×70 19 10 1.4 30.9 917
4×95 4×95 19 11.6 1.6 35.8 1258
4×120 4×120 19 13 1.6 39.1 1559
1×16+16 1×16 7 4.8 1.2 1×16 7 5.1 12.3 108
1×25+25 1×25 7 6 1.2 1×25 7 6.3 14.7 158
1×35+35 1×35 7 7 1.4 1×35 7 7.5 17.3 221
1×50+50 1×50 7 8.4 1.4 1×50 7 9 20.1 300
2×16+16 2×16 7 4.8 1.2 1×16 7 5.1 15.5 172
2×25+25 2×25 7 6 1.2 1×25 7 6.3 18.1 250
2×35+35 2×35 7 7 1.4 1×35 7 7.5 21.1 348
2×50+50 2×50 7 8.3 1.4 1×50 7 9 22.4 464
3×16+16 3×16 7 4.8 1.2 1×16 7 5.1 17.4 235
3×25+25 3×25 7 6 1.2 1×25 7 6.3 20.3 342
3×35+35 3×35 7 7 1.4 1×35 7 7.5 23.7 475
3×50+50 3×50 7 8.1 1.4 1×50 7 9 26.8 629
3×70+70 3×70 19 10 1.4 1×70 19 10.5 30.9 869
3×95+95 3×95 19 11.6 1.6 1×95 19 12.5 35.7 1200
3×35+16 3×35 7 7 1.4 1×16 7 4.8 22.2 445
3×50+25 3×50 7 8.1 1.4 1×25 7 6 24.8 585
3×70+35 3×70 19 10 1.4 1×35 7 7 30.9 815
3×95+50 3×95 19 11.6 1.6 1×50 7 8.1 35.7 1108
4×95+35 4×95 19 11.6 1.6 1×35 7 7 39.9 1385
3×120+70 3×120 19 13 1.6 1×70 19 10 39.1 1399

TNB SPECIFICATION(IEC 60502) ABC Cable

NUMBER OF CORES X NOMINAL CROSS SECTION OVERAL DIAMETER WEIGHT MAXIMUM CONDUCTOR RESISTANCE MINIMUM BREAKING LOAD CURRENT RATING
NO.×MM² MM KG/KM Ω/KM KN A
1×16+1×25 RM 15.3 160 1.910 2.5 72
3×16+1×25 RM 19.0 290 1.200 4.0 107
3×25+1×25 RM 23.2 400 0.868 5.5 132
3×35+1×25 RM 25.6 500 0.641 8.0 165
3×50+1×35 RM 30.0 680 0.443 10.7 205
3×70+1×50 RM 34.9 920 0.320 13.7 240
3×95+1×70 RM 40.6 1270 0.253 18.6 290
3×120+1×70 RM 44.1 1510 0.206 23.2 334
3×150+1×95 RM 49.2 1870 0.164 28.7 389
3×185+1×120 RM 54.9 2340 0.125 37.2 467
3×25+1×25+1×16 RM 23.2 470 1.910 2.5 72
3×35+1×25+1×16 RM 25.6 560 1.200 4.0 107
3×50+1×35+1×16 RM 30.0 740 0.868 5.5 132
3×70+1×50+1×16 RM 34.9 980 0.641 8.0 165
3×95+1×70+1×16 RM 40.6 1330 0.443 10.7 205
3×120+1×70+1×16 RM 44.1 1580 0.320 13.7 240
3×150+1×95+1×16 RM 49.2 1940 0.206 23.2 334
3×185+1×120+1×16 RM 54.9 2410 1.910 2.5 72

Aerial Bundled Cables to DES/LVC/ABC Specification & IEC 60502 (AL/XLPE)

Number of cores x nominal cross section min. breaking load of conductor strand Current rating in the air Outer diameter Total weight
mm² kN A mm kg/km
4×25 RM 3.5 84 21.5 420
4×35 RM 4.9 104 23.9 550
4×120+1×25 RM 16.8 246 43.8 1800
4×185+1×25 RM 25.9 332 50.7 2700

PDF Download

PDF Download

Why Choose Us

chanpin-why

Contact Us Immediately

Contact Us

Product Category

hot-sale product

Including 1, 2, 3, 4, 5, 1+1, 2+1, 3+1, 4+1 cores and so on, from 10mm2 to 240mm2 as follows, 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240m2.

Conductor: 1350-H19 Aluminum conductor, H68 round stranded conpressed(RM) Aluminium Conductor
Insulation: XLPE or PE or PVC, UV-resistant.

CU/XLPE, AAC/XLPE, AAAC/XLPE
CU/PE, AAC/PE, AAAC/PE, CU/XLPE, AAC/XLPE, AAAC/XLPE
AAC/XLPE, AAAC/XLPE

Duplex/Triplex/Quadruplex Service Drop Cable
Aluminum Overhead Service Drop Cable
LV Overhead insulated Cable
Overhead Service Cable
Overhead Line & Transmission Cables

CONDUCTOR: Single Conductor compressed or concentric HD aluminum, aluminum alloy, or ACSR

COVERING: Black, Linear Low-Density Polyethylene (LLDPE)

black extruded Cross-linked Polyethylene (XLPE)

Black Polyethylene (PE)

Medium-Density Polyethylene (MDPE)

High-Density Cross-linked Polyethylene (HDXLPE)

Contact Us Immediately